Ambient scenting and odor control systems normally emit odor, whether or not there is air flow in the environment, at specified time intervals. When used with this sensor, it provides a balanced working environment by operating the system in case of air flow in the environment.
In short, the Air Flow Sensor is a product made for the AC voltage switching of the ambient scent system.
- Working voltage: 90-240VAC
- Maximum current: 1A
- Short circuit protected
- Open circuit protected
- Working Temperature: 0 ° C ~ 60 ° C
- Suitable for industrial standards
Basic Working Algorithm:
- When the air flow sensor is plugged in, firstly, the resistance on the sensor heats up for about 1-1.5 minutes and its temperature reaches an average of 60 degrees.
- If there is air flow (circulation) in the environment, the resistance temperature drops, if it drops below the specified temperature, it gives AC output and operates the ambient odor system.
- If the ambient temperature rises above the specified temperature, the AC output turns off again.